Filter all posts by date
In additive manufacturing, understanding material performance under stress is crucial. TESCAN’s UniTOM XL offers a revolutionary solution for real-time analysis of 3D-printed...
13 Nov 2024
After two years of painstaking research, Henrik Lauridsen, Associate Professor at Aarhus University in Denmark, and Professor Michael Pederson from the Department of Medicine, entrusted the TESCAN micro-CT team to do a demo study aimed at using SPECTRAL...
23 Oct 2024
Dr. Sebastian Gruber, alongside a team of international researchers, contributed to a study titled "Pore Shape Matters – In-situ Investigation of Freeze-Drying Kinetics by 4D XCT Methods." This research, published in Food Research International, was a...
1 Oct 2024
We are thrilled to share an exclusive interview with Dr. Bernadette de Bakker, MD PhD, a visionary in the field of prenatal care. Dr. de Bakker’s pioneering research utilizes micro-CT imaging to create detailed 3D models of human fetuses, offering...
14 Aug 2024
Micro-CT is transforming medical diagnostics by allowing 3D examination of whole samples, preserving their contextual integrity. Researchers at Amsterdam UMC, under the direction of Dr. Bernadette de Bakker, are using micro-CT to study early human...
14 Aug 2024
TESCAN is excited to announce our participation in the Microscopy & Microanalysis (M&M) 2024 conference, taking place from July 29 to August 1 in Cleveland, Ohio, USA.
This esteemed event is a key gathering for experts in microscopy and microanalysis,...
23 Jul 2024
Micro-CT stands out as a versatile and powerful imaging technique that provides critical insights into the intricate 3D microarchitecture of electronic components. This application note explores the essential role micro-CT plays in both failure analysis...
9 Jul 2024
TESCAN micro-CT solutions lead the way inreal-time, 4D imaging of fast dynamic processes. Our dynamic CT solutions feature intuitive acquisition setups for long-term experiments, with hundreds of uninterrupted rotations using second-scale temporal...
17 Jun 2024
Tollund Man, a remarkably preserved bog body discovered in Denmark in 1950, has fascinated researchers and the public for decades. Now, thanks to advancements in scanning technology, scientists are gaining unprecedented insights into this ancient...
27 May 2024
When it comes to analytical approaches, TESCAN’s micro-CT and scanning electron microscopy (SEM) share common ground. Both techniques use contrast methods to analyze samples, highlighting features of interest as bright or dark phases.
7 May 2024
Advancements in micro-CT imaging have enabled scientists to understand and observe fluid migration in complex geological materials such as soils and reservoirs. The TESCAN dynamic micro-CT systems, in particular, have provided new insights into the...
23 Apr 2024
TESCAN is thrilled to be a leading presence at Interpore 2024 (May 13-16, Qingdao, China), the premier conference dedicated to porous media research.
22 Apr 2024
The study of fluid migration through porous media is essential for understanding various natural and industrial processes. These include the infiltration of rainwater into soil, the mobility of hydrocarbons in reservoirs, and the storage of e.g. carbon...
16 Apr 2024
Spectral micro-CT imaging is a unique imaging modality that allows absolute element identification through K-edge imaging. This is extremely useful for differentiating between multiple contrast agents, identifying elements in electronic components, and...
27 Mar 2024
Spectral CT can be applied for detailed analysis of soil samples to identify both the components of the soil as contaminants present in the subsurface. The example below shows how high-quality conventional micro-CT provides a very detailed view of the...
27 Mar 2024
Although a great tool for structural characterization of samples, conventional micro-CT can struggle to provide contrast between minerals with similar effective atomic number (the “total” average atomic number of the mineral) and/or density. A well-known...
27 Mar 2024
TESCAN has been at the vanguard of spectral CT technology, continuously improving both hardware and software. Over the past year, we have explored new ways to provide elemental and compositional information that compliments the high-quality structural...
27 Mar 2024
We recently had the pleasure of filming a video with University of Pau (UPPA) in the beautiful south of France. The DMEX Centre for X-ray Imaging at UPPA is our first customer to install a TESCAN UniTOM XL with the new Spectral CT option! As can be read...
1 May 2023
Having over a decade-long hands-on experience with micro-CT, scanned hundreds of samples and being amazed by new findings of their internal structure, one thing always came back as a question: What is the chemical composition of the features I see in 3D...
30 Jun 2022
In this blog series, dr. Wesley De Boever, micro-CT product marketing manager at TESCAN introduces the fundamental principles of micro-CT. In today’s blog post, we consider temporal resolution.
22 Apr 2022
In this blog series, dr. Wesley De Boever, micro-CT product marketing manager at TESCAN introduces the fundamental principles of micro-CT. And there is no better topic to kick off this blog series than spatial resolution.
Spatial resolution refers to...
21 Mar 2022
TESCAN, with a rich history spanning 30 years, has been a pioneer in the SEM and FIB-SEM market. The expansion into Micro CT technology was supported by the strategic acquisition of XRE in 2018, a dynamic spin-off from the University of Ghent’s Center...
15 Dec 2021
Learn the basics of microCT and dynamic image capture for dynamic process views in the laboratory.
7 Dec 2021
No results found
Our global team is available to answer questions about TESCAN MICRO-CT and other solutions.